Assistance 4D probe; recognize the probe by means of the ID code; switch the 4D travel signal by means of the  electrical relay to make the 4D probe do the job Commonly. 4.two.2 Key board The most crucial board can be divided into two areas: entrance-close of the most crucial board and back again-close of the principle board.

The person will not be allowed to open the handles and panel from the program, neither Take note: product disassemble is authorized. To make sure the procedure functionality and basic safety, only Mindray engineers or engineers approved by Mindray can accomplish servicing.

Take note: To the keep track of, the brightness adjustment comes ahead of distinction. Immediately after readjusting the observe’s contrast and brightness, modify all preset and peripheral configurations.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Slice off cable ties connecting the principle device to the display by diagonal slicing pliers, after which pull out the corresponding cable plugs.

Mindray’s new generation of black & white ultrasound procedure, DP-fifty Skilled, is equipped with Sophisticated imaging systems making it possible for deeper penetration and a lot quicker impression acquisition with larger resolution.

Site one hundred forty five Clean user interface Instruments: dry delicate fabric, moderate soapy drinking water  Technique:  Use dry soft fabric to wash the area with the process. In case the program is soiled, moisten the smooth fabric with moderate soapy water and wipe off any stains. Use dry delicate cloth to get rid of any moisture and permit all difficult surfaces to fully air-dry. Webpage 146: Cleanse The Peripherals

Uncover better diagnostic information and facts by way of prolonged see of the anatomical composition on all convex probes.

Permits usage of various scanned angles to form a single graphic, resulting in enhanced distinction resolution and improved visualization

five.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy  Take a look at Stage: Do changes as the way in which in screening the most depth. File the space by 20mm Every single phase about the longitudinal targets line utilizing the measurement caliper; Choose the value with the greatest error (to 20mm), work out the accuracy using the formulation underneath The measurement caliper needs to be positioned at the upper edge of the goal, Observe:... Web site 79 Transverse geometric positioning accuracy  Examination Action: Deal with the scan surface area of your phantom with drinking water or couple gel, gently Speak to the probe with the scan area Adjust the depth, creating the transverse targets for being displayed within the image. Adjust the main target issue to generally be posited beside the transverse targets (the standard is not clear) Regulate parameters like get, TGC, generating Every single transverse targets to be clearly exhibited. Web page 80 5.five.2.4 Blackout Location Examination Stage: Deal with the scan surface area in the phantom with drinking water or few gel, gently Make contact with the probe Using the scan floor Adjust the depth in a decrease value, and established the focus at the nearest spot to the scan surface. Minimize the value of parameters like AP, Get till the background sounds just is often viewed. Web site 81: Computer software Enhance And Routine maintenance

Soon after profitable connection, the freshly additional community printer title will probably be revealed from the printer driver checklist. Take note: In advance of link the community printer, ensure the ultrasound system as well as printer are in the exact same network domain, as well as network is Performing Ordinarily. The IP address plus the server identify needs to be legitimate, e.g. Page 47 DICOM Placing  Enter the AE Title on the ultrasound process, port and PDU based on the precise scenario, and afterwards simply click [Alright] to exit the monitor.

Explore superior diagnostic details by prolonged see in the anatomical structure on all linear probes

Notice: Right before inserting the connector in Dp50rb login to the probe port, inspect the connector pin. In case the pin is bent, tend not to use the probe until finally it's been inspected / fixed / replaced. Installing Peripherals For the versions of the supported peripherals, please make reference to “two.

Your Resource for deeper biopsy: allowing adjustments into the scan line to gain greater visibility from the needle, nerves and little vessels, guaranteeing the continuity of all knowledge.

Observe: Make certain that you may pull out and push into the IO board sockets vertically when pulling out and assembling the IO board assembly on the position on the take care of. Get rid of panhead screws with washers M3X6 (four) accustomed to secure the IO board, and afterwards you can consider out the IO board. Web page 116 Eliminate panhead screws with washers (two M3X6) which can be mounted on the leading unit, just take out the higher baffle and after that pull out two cables connecting the main board to the ability module assembly.